Implementasi Prototipe Sistem IOT Monitoring Kebocoran Gas dan Suhu Lingkungan Sebagai Upaya Pencegahan Kebakaran di Desa Tambak Rejo
DOI:
https://doi.org/10.32764/zc0zsg67Keywords:
IoT, LPG Gas Leak, ESP32, Fire Mitigation, Community Service.Abstract
Fires caused by LPG gas leaks remain a serious threat to public safety, especially in densely populated residential areas. Tambak Rejo Village faces a similar challenge, with the majority of residents using LPG for daily cooking without an adequate early warning system. This community service project aims to implement a prototype IoT-based monitoring system to detect gas leaks and ambient temperature as a fire risk mitigation measure. The method used is a participatory approach involving the community through outreach, prototype installation training, and operational assistance. The system utilizes an ESP32 microcontroller, an MQ-2 gas sensor, and a DHT22 temperature-humidity sensor connected to a web-based monitoring platform that can be accessed in real-time. The results of the project showed that the system successfully detected gas concentrations above 300 ppm and temperature increases above 35°C with an average response time of less than 2 seconds. The assisted community responded positively, with 85% of participants stating they felt safer and more alert after using the system. This project demonstrates that IoT-based technology can be an effective and affordable solution for increasing fire safety awareness and preparedness at the household level.
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Muhammad Bagus Cahyo A., Sujono Sujono

This work is licensed under a Creative Commons Attribution 4.0 International License.